As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
GOUGE LOCATED AT BS LT MLG STRUT SUPPORT FITTING. REMOVED ALL SHARP EDGES AND BLENDED SMOOTH. PERFORMED HFEC INSPECTION TO ENSURE TOTAL DAMAGE REMOVAL. FLAP PEEN AREA PE SRM 51-10-8. APPLIED AND BMS 10-11 TYPE 1 PRIMER. RESTORED AIRCRAFT TO NORMAL CONDITION, PERFORMED OPS AND FUNCTIONAL TESTS OF MLG SYSTEM. OPS CHECK OK IAW ECO 3242. RECEIVED 8110-3 APPROVAL. THIS IS CONSIDERED AN INTERIM REPAIR, PERMANENT REPAIR DUE NEXT C-CHECK. AIRCRAFT RETURNED TO SERVICE. (M)