What was found
MAIN ENTRY DOOR LOCK PIN FITTING CHAFED. NO LIMITS STATED IN SRM. BLENDED CHAFE AND INSPECTED FOR DAMAGE. RESTORED PROECTIVE FINISH IAW SRM 51-20. AFTER BLENDING, DAMAGE ACCEPTED FOR CONTINUDED OPERATION IAW REPAIR STATEMENT 340SDS034517.