What was found
DURING A SCHEDULED A CHECK INSPECTION, AN AREA CORROSION DAMAGE 1.25 INCHES WIDE & 0.875 INCHES LONG & 0.060 INCHES DEEP WAS FOUND ON THE LT STABILIZER AT ELEVATOR STATION 102.5. REMOVED CORROSION, SANDED, POLISHED, BLENDED, REWORKED AREA & APPLIED A DOUBLER REPAIR IAW FLIGHT VEHICLES CONSULTING DRAWING 53-14004-1, ACFT RETURNED TO SERVICE.