What was found
CA 1464/6 FILIFORM CORROSION WERE FOUND ON FUSELAGE EXTERNAL SKIN STATION 1016 BETWEEN LH SIDE STRINGER 17 TO 20 AND RH SIDE STRINGER 17-25. ALL CORROSION REMOVED AT FUSELAGE EXTERNAL SKIN AT STA 1016 BETWEEN S-17L TO S-20L AND S-17R TO S-25R. REMOVED 0.002" MATERIAL AND REMAINING 0.069" IS WITHIN ALLOWABLE LIMIT. AREA CLEAN AND PROTECTIVE IAW B737-300 SRM 51-10-2, 51-20-01 AND 53-00-01 ALLOWABLE DAMAGE 1 (R130).