What was found
CA 1464/94 CORROSION AT RH WINDOWS CUTOUT EDGE, BETWEEN STA 520 AND STA 540, 3 AREA (L:2",W:0.5")(L:0.5",W:0.5)(L:0.5",W:0.5"). ALL CORROSION REMOVED AT RH WINDOWS CUTOUT EDGE BETWEEN STA 520 AND STA E540 (L:2",W:0.5") (L:0.5",W:0.5") (L:0.5",W:0.5"). REMOVED 0.005", 0.007", 0.007" IS WITHIN ALLOWABLE LIMIT. AREA CLEAN AND PROTECTIVE IAW B737-300 SRM 51-10-2, 51-20-01 AND 56-20-2 ALLOWABLE DAMAGE 1 (R130).