What was found
DURING HEAVY MAINTENANCE VISIT AT TIMCO WHILE PERFORMING FUSELAGE-FORWARD SERVICE DURING AFT FRAME INSPECTION, FOUND CRACK ON INTERCOSTAL AT STA 332 WL 268 UPPER AFT STOP FITTING. FABRICATED -3 STIFFENER, -10 WEB -7, -8, AND -9 FILLERS IAW DWG NR 65C33288. REPAIRED IAW SRM 51-20-1 AND 51-30-2. ACFT RETURNED TO SERVICE. MATERIAL I.D. -3 STIFFENER AND -10 WEB 7075T6 .063 INCH. MATERIAL I.D. -7, -8, AND -9 FILLERS 2024T3 .050 INCH. TIMCO NON-ROUTINE CARD NR 28375. (X)