What was found
DURING LAP JOINT INSPECTION, FOUND FORWARD CARGO DOOR SCUFF PLATE STRUCTURE CRACKED 2 INCH ON BOTTOM LEFT SIDE AT STATION 450. REMOVED CRACKED AREA AND REPAIRED IAW SRM 51-40-3, FIGURE 1, AND SRM 51-30-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING LAP JOINT INSPECTION, FOUND FORWARD CARGO DOOR SCUFF PLATE STRUCTURE CRACKED 2 INCH ON BOTTOM LEFT SIDE AT STATION 450. REMOVED CRACKED AREA AND REPAIRED IAW SRM 51-40-3, FIGURE 1, AND SRM 51-30-02. (M)