What was found
DURING LAP JOINT INSPECTION, FOUND FORWARD CARGO DOOR SCUFF PLATE STRUCTURE CRACKED 1.5 INCH LONG ON BOTTOM LEFT SIDE AT STATION 465. REMOVED CRACKED AREA AND REPAIRED IAW SRM 51-40-3, FIGURE 1 AND SRM 51-30-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING LAP JOINT INSPECTION, FOUND FORWARD CARGO DOOR SCUFF PLATE STRUCTURE CRACKED 1.5 INCH LONG ON BOTTOM LEFT SIDE AT STATION 465. REMOVED CRACKED AREA AND REPAIRED IAW SRM 51-40-3, FIGURE 1 AND SRM 51-30-02. (M)