What was found
FLOOR SUPPORT STRUCTURE WEB AT STATION 440 TO 460 AND STRINGER 28L HAS LEVEL 2 CORROSION. FABRICATED REPAIR PART PER SRM 51-10-1. INSTALLED NEW PART PER SRM 51-10-6. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT STRUCTURE WEB AT STATION 440 TO 460 AND STRINGER 28L HAS LEVEL 2 CORROSION. FABRICATED REPAIR PART PER SRM 51-10-1. INSTALLED NEW PART PER SRM 51-10-6. (M)