What was found
DURING OP 16 MAINT CHECK, FOUND GOUGE IN FWD ENTRY DOOR OUTER SKIN AT GUST LOCK CUTOUT, .5 IN BY .25 IN. BLENDED DAMAGED AREA AND INSTALLED REPAIR DOUBLER TO OUTER SKIN PER SRM 52-05, FIG 20.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND GOUGE IN FWD ENTRY DOOR OUTER SKIN AT GUST LOCK CUTOUT, .5 IN BY .25 IN. BLENDED DAMAGED AREA AND INSTALLED REPAIR DOUBLER TO OUTER SKIN PER SRM 52-05, FIG 20.