What was found
DURING OP 16 MAINT CHECK, FOUND FWD CARGO CORROSION AT GROUND STUD ON FLOOR SUPPORT AT STA 544, LBL 10. REPLACED FLOOR SUPPORT PANEL PER STD PROCESSING MANUAL 6-70-01, AND INSTALLED PER SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND FWD CARGO CORROSION AT GROUND STUD ON FLOOR SUPPORT AT STA 544, LBL 10. REPLACED FLOOR SUPPORT PANEL PER STD PROCESSING MANUAL 6-70-01, AND INSTALLED PER SRM 51-40-02.