What was found
DURING CHECK-C MAINT, FOUND CORROSION ON MEMBRANE BETWEEN STA 1155 TO 1174 RT SIDE, 58 IN RBL. REMOVED SURFACE COROSION ON MEMBRANE STA 1155 TO 1174, RT SIDE, PER SPM 6-80-01, PAGE 1, AND SRM 51-10-03. PRIMED INST FASTENERS PER SRM 53-30-0 PAGE 1 THAT WERE REMOVED IN REMOVING FIBERGLAS ANGLE.