What was found
DURING CHECK-C MAINT, FOUND CORROSION AT MEMBRANE FLOOR PAN ALONG LONGERON 18L, FROM STA 1107 THROUGH 1149. REMOVED LIGHT AND MODERATE CORROSION ON THE LT FLOOR MEMBRANE, LONGERON 18L FROM STA 1107 TO 1149 PER SPM 6-80-01, PAGE 1-3. REPAIRED AREA STA 1118 TO 1123 PER SRM 53- 01, FIG 4 SHEET 3 PAGE 18. TREATED AREA FROM STA 1107 TO 1149 LONGERON 18L FLOOR MEMBRANE PER SRM 51-10-3.