What was found
DURING OP 16 MAINT CHECK, FOUND CORROSION AROUND NUT PLATE HOLES ON FLOOR SUPPORT, STA 200 RBL 5 IN TO LBL 5 IN. REMOVED CORROSION PER SPM 6-80-01, PAGE 1. FABRICATED FLOOR SUPPORT PER SPM 6-70-01, PAGE 2 AND 3, PARAGRAPH 4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND CORROSION AROUND NUT PLATE HOLES ON FLOOR SUPPORT, STA 200 RBL 5 IN TO LBL 5 IN. REMOVED CORROSION PER SPM 6-80-01, PAGE 1. FABRICATED FLOOR SUPPORT PER SPM 6-70-01, PAGE 2 AND 3, PARAGRAPH 4.