What was found
DURING OP 16 MAINT CHECK AT STA 936, LBL 6 IN, THE AFT SIDE OF KEEL BEAM STRUCTURE HAD 2 EA 5 IN VERTICAL CRACKS, ONE AT RADIUS 1 1/8 AND SECOND AT RADIUS 1/2 IN, BOTH ON SAME MEMBER. REPLACED PER SRM 53-05, FIG 81 PAGE 267, DRAWING NUMBER REF 5936360.