What was found
DURING OP 16 MAINT CHECK, FOUND CABIN FLOOR PANEL 23 HAD CORROSION. FABRICATED NEW FLOOR PANEL PER SRRM 53-00-104, PAGE 201.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND CABIN FLOOR PANEL 23 HAD CORROSION. FABRICATED NEW FLOOR PANEL PER SRRM 53-00-104, PAGE 201.