What was found
DURING OP 16 MAINT CHECK, FOUND CABIN FLOOR PANEL MEMBER NUMBER 12 HAD CORROSION ON IT. REF CPCP TASK C46-53306 FWD GALLEY AREA. REMOVED CORROSION PER SPM 51-10-3 AND TREATED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND CABIN FLOOR PANEL MEMBER NUMBER 12 HAD CORROSION ON IT. REF CPCP TASK C46-53306 FWD GALLEY AREA. REMOVED CORROSION PER SPM 51-10-3 AND TREATED.