What was found
DURING OP 16 MAINT CHECK, STRINGER 4L WAS CRACKED AT STA 200. REPLACED STRINGER 4L AT STA 155 TO 229 PER SRM 51-01, PAGE 1. FASTENERS PER SRM 51-30-02 AND 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, STRINGER 4L WAS CRACKED AT STA 200. REPLACED STRINGER 4L AT STA 155 TO 229 PER SRM 51-01, PAGE 1. FASTENERS PER SRM 51-30-02 AND 51-30-5.