What was found
DURING OP 16 MAINT CHECK, FOUND TEMPORARY FORMER REPAIR AT STA 980, STRINGER 16L TO 18L. REPLACED FORMER FRAME WITH NEW PER TWA SP. INSTALLED FRAME SPLICE REPAIR BETWEEN LONGERON 11L AND 10L PER SRM 53-03, PAGE 131. INSTALLED SEALER PER SRM 51-20.