What was found
DURING CHECK-C MAINT, THE LT WING OTBD TE FLAP, OTBD FWD CORNER HAD HOLES. CLEANED UP AREA. FILLED AND INSTALLED A 4..5 INCH DIA FIBERGLAS LAY UP REPAIR PER SRM 51-70-17. ALSO PRIMED AND PAINTED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT, THE LT WING OTBD TE FLAP, OTBD FWD CORNER HAD HOLES. CLEANED UP AREA. FILLED AND INSTALLED A 4..5 INCH DIA FIBERGLAS LAY UP REPAIR PER SRM 51-70-17. ALSO PRIMED AND PAINTED.