What was found
DURING OP 16 MAINT CHECK, FOUND CORROSION ON FLOOR SUPPORT ANGLE, STA 200 LBL 0 TO 20 INCHES. INSTALLED NEW FLOOR SUPPORT MADE FROM TWA PN S2652479-1200, WITH RIVETS PER SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND CORROSION ON FLOOR SUPPORT ANGLE, STA 200 LBL 0 TO 20 INCHES. INSTALLED NEW FLOOR SUPPORT MADE FROM TWA PN S2652479-1200, WITH RIVETS PER SRM 51-30-2.