What was found
DURING CHECK-C MAINT, IN RT WHEEL WELL, FWD INBD CORNER AT KEEL BEAM AREA, ATTACHMENT ANGLE CRACKED IN RADIUS .5 INCH LONG. REPLACED ATTACH ANGLE PER SPM 6-70-01, PAGE 3 APRA 4B AND DOUGLAS DRAWING 9936368.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT, IN RT WHEEL WELL, FWD INBD CORNER AT KEEL BEAM AREA, ATTACHMENT ANGLE CRACKED IN RADIUS .5 INCH LONG. REPLACED ATTACH ANGLE PER SPM 6-70-01, PAGE 3 APRA 4B AND DOUGLAS DRAWING 9936368.