What was found
DURING OP 16 MAINT CHECK, FOUND CORROSION ON FLOOR SUPPORT AT STA 1155, BETWEEN NUMBER 3 AND 4 GALLEYS TIE DOWN TRACK. REPLACED FLOOR SUPPORT PER SPM 6-70-01. PRIMED AND PAINTED PER SRM 51-10-03.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK, FOUND CORROSION ON FLOOR SUPPORT AT STA 1155, BETWEEN NUMBER 3 AND 4 GALLEYS TIE DOWN TRACK. REPLACED FLOOR SUPPORT PER SPM 6-70-01. PRIMED AND PAINTED PER SRM 51-10-03.