What was found
DURING CHECK-C MAINT, THE RT WING NR 7 LE SLAT HAD A REPAIR 2 FT 9 IN BY 4.75 INCH THAT WAS DELAMINATED AT THE OBTD TE. INSTALLED A 3 FT BY 4.75 INCH HOT BOND REPAIR PER SRM 51-70-10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT, THE RT WING NR 7 LE SLAT HAD A REPAIR 2 FT 9 IN BY 4.75 INCH THAT WAS DELAMINATED AT THE OBTD TE. INSTALLED A 3 FT BY 4.75 INCH HOT BOND REPAIR PER SRM 51-70-10.