What was found
DURING CHECK-C MAINT, FOUND RUSTED BOLT ON WINDOW FRAME BETWEEN STA 446 AND 465. REMOVED 2 RUSTED BOLTS AND INSTALLED 2 NEW BOLTS AND WASHERS PER SPM 6-30-07.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT, FOUND RUSTED BOLT ON WINDOW FRAME BETWEEN STA 446 AND 465. REMOVED 2 RUSTED BOLTS AND INSTALLED 2 NEW BOLTS AND WASHERS PER SPM 6-30-07.