What was found
DURING OP 16 MAINT CHECK HAD CRACK ON FITTING ON O/B FLOOR SUPPORT BEAM AT STA 996, LBL 60 INCHES. INSTALLED NEW FITTING (P/N 5913700-IN) PER 5910163 DRAWING WITH HI-LOKS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 16 MAINT CHECK HAD CRACK ON FITTING ON O/B FLOOR SUPPORT BEAM AT STA 996, LBL 60 INCHES. INSTALLED NEW FITTING (P/N 5913700-IN) PER 5910163 DRAWING WITH HI-LOKS.