What was found
DURING CHECK-C MAINT, IN THE C3 CARGO COMPT FOUND CORROSION AT STA 1212 TO 1210, BETWEEN LONGERON 30 TO 29R ON U CHANNEL. REMOVED AND REPLACED U CHANNEL PER SPM 6-70-01. INSTALLED FASTENERS PER SRM 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT, IN THE C3 CARGO COMPT FOUND CORROSION AT STA 1212 TO 1210, BETWEEN LONGERON 30 TO 29R ON U CHANNEL. REMOVED AND REPLACED U CHANNEL PER SPM 6-70-01. INSTALLED FASTENERS PER SRM 51-30-5.