What was found
DURING CHECK-C MAINT, FOUND CORROSION ON LOWER FWD SIDE OF PRESSURE BULKHEAD DOUBLER, RT OF CENTER LINE. REMOVED AND REMANUFACTURED DOUBLER PER SRM 53-14-3, FIG 7 SHEET 1 AND 4 USING 70756T6 0.080 FASTENERS PER SRM 51-60-0 AND PER DOUGLAS DRAWING 5930760.