What was found
DURING CHECK-C MAINT AT STA 434 FOUND LEVEL 2 CORROSION ON T ANGLE FWD END OF INTERCOSTAL, LONGERON 29R. INSTALLED NEW T ANGLE (P/N 491258-501). SECURED TO STRUCTURE WITH HI-LOK 326 PER SRM 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT AT STA 434 FOUND LEVEL 2 CORROSION ON T ANGLE FWD END OF INTERCOSTAL, LONGERON 29R. INSTALLED NEW T ANGLE (P/N 491258-501). SECURED TO STRUCTURE WITH HI-LOK 326 PER SRM 51-30-5.