What was found
DURING OP 16 MAINT CHECK ON LT WING, FOUND DENTS IN LEADING EDGE OF NUMBER 3 LEADING EDGE SLAT, DENT LOCATED 13 INCHES I/B FROM O/B END OF SLAT WAS 1 INCH WIDE BY 1 INCH LONG AND 0.050 INCH DEEP, DENT LOCATED 18 INCHES I/B FROM O/B END OF SLAT WAS .75 INCH LONG, 1 INCH WIDE AND 0.040 DEEP, AND DENT LOCATED 26 INCHES O/B FROM I/B END OF SLAT WAS 1 INCH LONG BY 1 INCH WIDE AND 0.040 IN DEEP. ON ALL 3 DENTS, ACCOM HIGH FREQ EDDY CURRENT PER NDT 51-00-03 PART 6 AND NO CRACKS FOUND. REPAIRED DENTS PER SRM 57-03 FIG 14A.