What was found
DURING CHECK-C MAINT AT CABIN STA 1155, LBL 33, FOUND CORROSION ON FLOOR SUPPORT BETWEEN NUMBER 2 AND 3 TRACKS. FABRICATED AND INSTALLED NEW SUPPORT PER SRM 53-14-3, FIG 12 AND SPM 6-70-01 PAGE 3. PROTECTIVE TREATMENT OF SUPPORT PER SRM 51-10-3. INSTALLED WITH ORIGINAL TYPE FASTENERS PER SRM 51-30-0.