What was found
DURING CHECK-C MAINT, FOUND CORROSION IN AFT CARGO THRESHOLD PLATE, STA 1212. REMOVED CORROSION PER SPM 6-80-01 PAGE 1 ITEMS 3A AND B, AND PAGE 2 AND 3. REPAIRED PER SRM 53-01 FIG 4 SHEET 3, AND ARA 16728A DATED 5-26-00, SRM 51-60-0 PAGE 36, SRM 51-60-0 PAGE 8. CORROSION TREATED PARTS PER SRM 51 AND DRAWING 5910085 AND 5930483.