What was found
DURING CHECK-C MAINT, FOUND CORROSION ON FLOORBEAM AT STA 1309, LOCATED 6 INCHES LEFT OF CENTER LINE. REMOVED AND REPLACED FLOOR SUPPORT. USED TWA (P/N 56-2789) TO FABRICATE PER SRM 53-14-3, PAGE 49, AND USED HI-LOKS PER SRM 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT, FOUND CORROSION ON FLOORBEAM AT STA 1309, LOCATED 6 INCHES LEFT OF CENTER LINE. REMOVED AND REPLACED FLOOR SUPPORT. USED TWA (P/N 56-2789) TO FABRICATE PER SRM 53-14-3, PAGE 49, AND USED HI-LOKS PER SRM 51-30-5.