What was found
FOUND A .5 INCH CRACK IN THE I/B FLANGE OF NUMBER 2 LONGERON 6L AT STA 639. SECTION CUT OUT, LONGERON REPAIR SPLICE PUT IN PER SRM 53-02-0, FIG 18 SHEET 1. CHECK-C 2-25-00 STL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND A .5 INCH CRACK IN THE I/B FLANGE OF NUMBER 2 LONGERON 6L AT STA 639. SECTION CUT OUT, LONGERON REPAIR SPLICE PUT IN PER SRM 53-02-0, FIG 18 SHEET 1. CHECK-C 2-25-00 STL.