What was found
DURING CHECK-C MAINT ON LT WING THE NUMBER 1 FLAP BOTTOM 2 FEET FROM I/B EDGE WAS FOUND WITH A 2 INCH DIAMETER DELAMINATION, 6 INCHES FROM THE T/E. INSTALLED A 5 INCH DIAMETER HOT BOND REPAIR, PRIMED AND PAINTED PER SRM 51-70-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT ON LT WING THE NUMBER 1 FLAP BOTTOM 2 FEET FROM I/B EDGE WAS FOUND WITH A 2 INCH DIAMETER DELAMINATION, 6 INCHES FROM THE T/E. INSTALLED A 5 INCH DIAMETER HOT BOND REPAIR, PRIMED AND PAINTED PER SRM 51-70-05.