What was found
DURING CHECK-C MAINT, THE SILL AREA IN AFT CABIN HAD CORROSION ON MEMBRANE WIDTH OF DOOR, INTERGRANNULAR BELOW AFT GIRT BAR MOUNT FITTING, STA 1136L TO 1193L, LBL 50 TO LBL 54. REMOVED LIGHT TO MODERATE CORROSION. TREATED, PRIMED AND PAINTED PER SRM 51-10-03 AND SPM 6-80-01. ATTACHED CUTOUT REPAIR PER SRM 53-01, PAGE 18 AND FABRICATED T ANGLE SUPPORT PER DRAWING 9930612.