What was found
DURING CHECK-C MAINT, FOUND CRACK IN ANGLE FOR LOUVERS AT STA 1463, RT SIDE. FABRICATED NEW ANGLE FROM 7075-T6, 0.080 PER DOUGLAS DRAWING 9923630. TREATED PER SRM 51-10-3 AND INSTALLED ON ACFT PER SRM 51-30-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT, FOUND CRACK IN ANGLE FOR LOUVERS AT STA 1463, RT SIDE. FABRICATED NEW ANGLE FROM 7075-T6, 0.080 PER DOUGLAS DRAWING 9923630. TREATED PER SRM 51-10-3 AND INSTALLED ON ACFT PER SRM 51-30-05.