What was found
DURING CHECK-C MAINT FOUND FUSELAGE DENT AT STA 218L, BETWEEN LONGERON 18L AND 19L, 3 .625 INCH LONG, 2 .375 INCH WIDE AND 0.150 DEEP. ACCOMP EDDY CURRENT INSP PER NDT 51-00-03 AND NO CRACK FOUND. CUT OUT DAMAGED AREA. INSTALLED A FLUSH DOUBLER 16 BY 17 INCHES FROM 0.050 2024T3 WITH A FINGER DOUBLER PER SSRM 53-10-107 PAGE 202.