What was found
DURING CHECK-C MAINT, ON RT WING L/E SLAT NUMBER 11, O/B END LOWER SURFACE OF THE WEDGE HAD DELAMINATION. INSTALLED REPLACEMENT HONEYCOMB CORE AND 3 INCH BY 9 INCH EXTERNAL DOUBLER PER SRM 51-70-10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT, ON RT WING L/E SLAT NUMBER 11, O/B END LOWER SURFACE OF THE WEDGE HAD DELAMINATION. INSTALLED REPLACEMENT HONEYCOMB CORE AND 3 INCH BY 9 INCH EXTERNAL DOUBLER PER SRM 51-70-10.