What was found
DURING CHECK-C MAINT ON RT WING, THE L/E SLAT NUMBER 12 I/B END LOWER SURFACE OF THE T/E WEDGE HAD DELAMINATION. INSTALLED REPLACEMENT HONEYCOMB CORE AND 12 INCH BY 10 INCH EXTERNAL DOUBLER PER SRM 51-70-10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT ON RT WING, THE L/E SLAT NUMBER 12 I/B END LOWER SURFACE OF THE T/E WEDGE HAD DELAMINATION. INSTALLED REPLACEMENT HONEYCOMB CORE AND 12 INCH BY 10 INCH EXTERNAL DOUBLER PER SRM 51-70-10.