What was found
DURING OP 15 MAINT CHECK, ON THE AFT BULKHEAD DOOR, FOUND A CRACK IN DOOR FRAME APPROX 6 INCHES LONG AT LT AFT EDGE, 35 INCHES ABOVE BOTTOM OF DOOR. REPLACED FRAME SECTION PER SPM 6-70-01 AND DOUGLAS DRAWING 9915565.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 15 MAINT CHECK, ON THE AFT BULKHEAD DOOR, FOUND A CRACK IN DOOR FRAME APPROX 6 INCHES LONG AT LT AFT EDGE, 35 INCHES ABOVE BOTTOM OF DOOR. REPLACED FRAME SECTION PER SPM 6-70-01 AND DOUGLAS DRAWING 9915565.