What was found
DURING OP 15 MAINT CHECK THE FWD ENTRY AREA HAD CORROSION ON FLOOR SUPPORT BEAM AT STA 200, LBL 0 TO 20 INCHES. FABRICATED AND REPLACED CORRODED PART PER SRM 53-11-1, FIG 11 SHEET 1 AND 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 15 MAINT CHECK THE FWD ENTRY AREA HAD CORROSION ON FLOOR SUPPORT BEAM AT STA 200, LBL 0 TO 20 INCHES. FABRICATED AND REPLACED CORRODED PART PER SRM 53-11-1, FIG 11 SHEET 1 AND 2.