What was found
DURING OP 15 MAINT CHECK IN THE FWD CABIN THE FLOOR SUPPORT AT STA 160 TO 200, LBL 44, WAS CORRODED. REMOVED FLOOR SUPPORT. FABRICATED NEW PART PER DRAWING 9910078 AND SRM 51-10-3. INSTALLED PER SRM 51-30-0 AND 51-10-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 15 MAINT CHECK IN THE FWD CABIN THE FLOOR SUPPORT AT STA 160 TO 200, LBL 44, WAS CORRODED. REMOVED FLOOR SUPPORT. FABRICATED NEW PART PER DRAWING 9910078 AND SRM 51-10-3. INSTALLED PER SRM 51-30-0 AND 51-10-2.