What was found
DURING OP 15 MAINT CHECK, FOUND 37 INCHES OF FLOOR SUPPORT CORRODED BETWEEN STA 162 AND 200, RBL 43. REPLACED OLD SUPPORT WITH NEW. MADE PER SPM 6-70-1. INSTALLED PER SRM 51-30 PAGE 18.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 15 MAINT CHECK, FOUND 37 INCHES OF FLOOR SUPPORT CORRODED BETWEEN STA 162 AND 200, RBL 43. REPLACED OLD SUPPORT WITH NEW. MADE PER SPM 6-70-1. INSTALLED PER SRM 51-30 PAGE 18.