What was found
DURING OP 15 MAINT CHECK FOUND CORROSION ON FLOOR SUPPORT AT STA 160, RBL 0 TO 53. FABRICATED NEW SUPPORT PER SRM 53-10-1 AND SPM 6-70-01 AND REPLACED. INSTALLED PER SRM 51-30 PAGE 18.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OP 15 MAINT CHECK FOUND CORROSION ON FLOOR SUPPORT AT STA 160, RBL 0 TO 53. FABRICATED NEW SUPPORT PER SRM 53-10-1 AND SPM 6-70-01 AND REPLACED. INSTALLED PER SRM 51-30 PAGE 18.