What was found
DURING CHECK-C MAINT AT LBL 54 INCHES, STA 1174 AT AFT GALLEY DOORWAY, AFT BOTTOM CORNER, FOUND HEAVY CORROSION AT FLOOR TRACK AREA. REPLACED TRACK PER SRM 51-30-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT AT LBL 54 INCHES, STA 1174 AT AFT GALLEY DOORWAY, AFT BOTTOM CORNER, FOUND HEAVY CORROSION AT FLOOR TRACK AREA. REPLACED TRACK PER SRM 51-30-1.