As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING CHECK-C MAINT IN AFT CARGO COMPT FOUND DOOR BEAM CORRODED AT STA 1155 TO 1211. REMOVED CORROSION PER SPM 6-80-01. BEAM OUT OF LIMITS AND REPLACED PER DRAWING 5936038-501. INSTALLED PER SRM 51-30-02 AND 51-30-05. TREATED AND PAINTED PER 51-10-3.