What was found
DURING CHECK-C MAINT THE FUSELAGE SKIN HAD A DENT AND SCRATCH AT STA 1278 TO 1308, LONGERON 18L TO 19R, 2.25 INCH BY 1.625 INCH BY 0.030 DEEP. REPAIRED DENT/SCRATCH WITH TITANIUM DOUBLER AND PLUG REPAIR PER SRM 53-04, FIG 38, VIEW H. AREA EDDY CURRENT INSPECTED FOR CRACKS AND NONE FOUND.