What was found
DURING CHECK-C MAINT FOUND FLOOR SUPPORT CORRODED AT STA 160 TO 180, RBL 53 INCHES. FABRICATED NEW FLOOR SUPPORT PER DRAWING 9936534. PAINTED PER SRM 51-10-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT FOUND FLOOR SUPPORT CORRODED AT STA 160 TO 180, RBL 53 INCHES. FABRICATED NEW FLOOR SUPPORT PER DRAWING 9936534. PAINTED PER SRM 51-10-3.