What was found
DURING CHECK-C MAINT FOUND CORROSION ON FLOOR SUPPORT BETWEEN STA 160 AND 200, 53 INCHES RBL. FABRICATED NEW TRACK AND INSTALLED PER SRM 51-30-2. TREATED PART PER SRM 51-10-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT FOUND CORROSION ON FLOOR SUPPORT BETWEEN STA 160 AND 200, 53 INCHES RBL. FABRICATED NEW TRACK AND INSTALLED PER SRM 51-30-2. TREATED PART PER SRM 51-10-3.